Product: Instant Digital Download (PDF)
Diagnose front-drive motor and inverter thermal faults using the OEM diagnostic procedures for motor overheating, winding-temperature sensor sampling, IGBT temperature and IPM radiator overheating, including resolver temperature-sensor resistance testing, VDS controller data-stream checks, cooling-system diagnosis and OEM-directed motor/controller actions.
Years Covered:
2022, 2023, 2024, 2025
Vehicle Specification:
SC2E, e-Platform 3.0 400V, FWD, RHD
Excludes:
2026+ BYD ATTO 3 Evo, 800V RWD/AWD architecture, 74.8 kWh Cell-to-Body battery pack, and Left-Hand Drive (LHD) variants.
DTCs Covered
- P1BB200 — General Overtemperature Alarm for Front Drive Motor
- P1BB298 — Severe Overheating Alarm for Front Drive Motor
- P1BF200 — Abnormal Sampling of Front Drive Motor Winding Temperature Sensor
- P1BB300 — Front Drive Motor Controller IGBT-NTC General Overtemperature Alarm
- P1BAC00 — General Overtemperature Alarm for IGBT Core Temperature of Front Drive Motor Controller
- P1BC700 — Front Drive Motor Controller IPM Radiator Overheat Fault
Diagnostic Coverage
- OEM high-voltage and electric-drive safety precautions
- VDS power-domain and front-drive motor-controller DTC confirmation, clearing and recheck
- Cooling-system fault diagnosis
- P1BB200 general front-drive motor overtemperature diagnosis
- P1BB298 severe front-drive motor overheating diagnosis
- P1BF200 winding-temperature sensor sampling diagnosis
- Resolver connector terminal 1 ↔ terminal 6 winding-temperature sensor testing
- OEM winding-temperature sensor resistance references:
- -30°C — 2280 kΩ
- -20°C — 1190 kΩ
- -10°C — 646.9 kΩ
- 0°C — 364.9 kΩ
- 10°C — 212.5 kΩ
- 20°C — 127.7 kΩ
- 30°C — 78.88 kΩ
- 40°C — 50.04 kΩ
- Drive-motor assembly replacement path where the winding-temperature sensor check is abnormal
- Integrated intelligent front-drive controller replacement and DTC recheck for applicable motor-overtemperature faults
- Approximately 10-minute normal road-operation verification
- P1BB300 IGBT-NTC overtemperature diagnosis
- P1BAC00 IGBT core-temperature overtemperature diagnosis
- 2-hour normal-temperature stabilization for IGBT controller-temperature diagnosis
- VDS IGBT temperature data-stream check
- Integrated intelligent front-drive controller replacement where the applicable IGBT-temperature fault remains
- P1BC700 IPM radiator overheat diagnosis
- 2-hour normal-temperature stabilization for the IPM radiator diagnostic path
- Approximately 10-minute normal-driving verification for P1BC700
- Integrated intelligent front-wheel drive controller software update and DTC recheck for P1BC700
- Controller replacement where P1BC700 remains after the applicable OEM software/recheck path
- Clear distinction between the winding-temperature resistance-reference table and the unspecified OEM overtemperature trigger thresholds
Included Links to OEM Source Material
Reference links are provided within the guide for:
- Complete OEM Diagnostic Manual
- Electronic Wiring Diagram
- Repair Manual
The linked OEM source documents are separate reference resources and are not included with this Diagnostic Guide.